Positive Displacement Pump Selection

Pump sets suitable for clean liquids

Pump

Maximum

Capacity

Maximum

Total Head

Motor

Rating

Max. Total

Suction Lift

Pump

rev/min

m3/hr US gpm

m

H2O

bar

ft

H2O

lb/in2

up to

75 cSt

1000

cSt

Water

and to

75 cSt

1000

cSt

hp hp

m

H2O

ft

H2O

m

H2O

ft

H2O

 
L75 1.5 6.6 30 3 100 45 0.75 1 7 23 6.1 20 1760
L100 3 13.2 30 3 100 45 1.5 2 7 23 6.1 20 1760
L125 5 21.6 30 3 100 45 1.5 3 7 23 6.1 20 1440
L150 10 43.2 30 3 100 45 3 5.5 6.7 22 6.1 20 1370
L200 15 66 30 3 100 45 5.5 7.5 6.7 22 5.4 18 1250
L300 30 132 30 3 100 45 10 15 6 20 5.4 18 850
L400 60 264 30 3 100 45 15 30 6 20 5.4 18 850
 
H75 1.5 6.6 45 4.5 150 65 0.75 1.5 7 23 6.1 20 1550
75 7.5 250 110 1
H100 3 13.2 53 5.3 175 75 1.5 3 7 23 6.1 20 1500
75 7.5 250 110 2
H125 5 21.6 45 4.5 150 65 2 5.5 7 23 6.1 20 1350
75 7.5 250 110 3
H150 10 43.2 60 6 200 87 5.5 7.5 7 23 6.1 20 1250
75 7.5 250 110 7.5
H200 15 66 45 4.5 150 65 5.5 10 6.7 22 6.1 20 1030
75 7.5 250 110 7.5
H300 22.5 100 53 5.3 175 75 10 20 6 20 6 20 960
75 7.5 250 110 15
H400 45 200 53 5.3 175 75 15 40 6 20 6 20 960
75 7.5 250 110 20

Pump sets suitable for dirty liquids
Pump Capacity

Maximum

Total Head

Motor

Rating

Max. Total

Suction Lift

Pump

rev/min

m3/hr US gpm

m

H2O

bar

ft

H2O

lb/in2

up to

75 cSt

2500

cSt

Water

and to

75 cSt

2500

cSt

hp hp

m

H2O

ft

H2O

m

H2O

ft

H2O

 
L100 2 9 30 3 100 45 1 2 8.2 27 5.2 17 1200
L125 3 13.2 30 3 100 45 1.5 3 8.2 27 5.2 17 900
L150 6 26.4 30 3 100 45 2 5.5 8.2 27 5.2 17 850
L200 10 44.4 30 3 100 45 4 7.5 7.5 25 5.2 17 850
L300 20 90 30 3 100 45 7.5 7.5 7.5 25 4.5 15 570
L400 40 180 30 3 100 45 10 30 7.5 25 4.5 15 570
 
H100 2 9 53 5.3 175 75 1 3 8.2 27 5.2 17 1000
75 7.5 250 110 1.5
H125 3 13.2 45 4.5 150 65 1.5 5.5 8.2 27 5.2 17 850
75 7.5 250 110 2
H150 6 26.4 55 5.5 180 78 3 7.5 8.2 27 5.2 17 800
75 7.5 250 110 4
H200 10 44.4 55 5.5 180 78 4 10 7.5 25 5.2 17 720
75 7.5 250 110 5.5
H300 15 55 60 6 200 87 7.5 20 7.5 25 5.2 17 650
75 7.5 250 110 7.5
H400 30 132 60 6 200 87 15 40 7.5 25 5.2 17 650
75 7.5 250 110 15

The capacity of each Megator positive displacement pump is directly proportional to the pump speed.  Therefore any capacity can be interpolated from the tables above.  The pump curve is therefore a straight line.

 

Example 

 

Application = clean water

Total head = 22 metres

Capacity required = 8m3/hr

  1. From the clean liquids table select a pump with a maximum total head equal to or greater than total head required

  2. Select a pump with a capacity equal to or greater than the capacity required

  3. Divide the listed pump speed by the listed capacity

  4. Multiply answer by the required capacity

L150 = 10m3/hr @ 1370 rpm

1370 ÷ 10 = 137

8m3/hr x 137 = 1096 rpm

 

Pump required = L150 @ 1096 rpm 

Giving 8m3/hr at a maximum head of 30 metres


The Megator sliding shoe pump delivers its rated capacity at any head and at any suction lift within its range. The head developed is the head imposed by the system at the rated flow. A head capacity curve on the conventional basis would be a vertical straight line.

Intermediate Capacities
For intermediate capacities, the pumps can be run at speeds lower than those listed in the tables. The head is independent of the speed. The capacity, and the horsepower at a given head, are approximately proportional to the speed.

Motor Ratings
The standard motors listed provide for the maximum heads and, in the case of type H pumps, for an intermediate head. Where the heads are substantially below those listed , smaller motors can frequently be used.

Suction Lift
The suction lifts listed assume normal temperature. Installations combining suction lift with temperatures above normal should be referred to Megator.

Temperature
The ratings listed in the tables are valid for temperatures up to  38oC (100oF), subject to the above note on suction lift. Where higher temperatures are involved, it is advisable to consider them in conjunction with the other working conditions and such cases should be referred to Megator.

Dirty Liquids
Reduced pump speeds give a markedly increased resistance to wear, and the high suction ratings are recommended for dirty liquids. Under severe conditions still lower speeds may provide the most economical installation.

 

Standard ratings Adobe Acrobat PDF format (39KB)

L75-H200 Belt driven pump dimensions Adobe Acrobat PDF (35 KB)

L75-H200 Belt driven space saver pump dimensions Adobe Acrobat PDF (74 KB)

L75-H200 Direct coupled pump dimensions Adobe Acrobat PDF (36 KB)

L300-H300 Belt driven pump dimensions Adobe Acrobat PDF (92 KB)

L300-H300 Direct coupled pump dimensions Adobe Acrobat PDF (100 KB)

L400-H400 Belt driven pump dimensions Adobe Acrobat PDF (36 KB)

L400-H400 Direct coupled pump dimensions Adobe Acrobat PDF (108 KB)

 

 

• Home • Sliding Shoe Pump • Diaphragm Pumps • Lobe Pump • Mega Flex Vane Pump • Salarollpump • Oil Dispersant Systems • Oil Water Separators • Oil Skimmers • Floating Booms • Oil Absorbents • Oil Spill Kits • Oil Spill Trailer • Floating Strainers • Cyclonator • Contact Us • Links •

 

Download Windows Media player    Download Adobe Acrobat reader

 

Copyright © Megator Limited 2004

All rights reserved

Registered Office: Hendon SR1 2NQ England 404130